@AN (Analog Input)

[Function]

DESCRIPTION:

@AN returns the value of an analog input as a voltage (+/-10V). Note that the @AN command is a
function, which means that it does not follow the convention of other commands, and does not require the
underscore when used as an operand. The resolution is 14 bit, or 1.2mV per bit. To read analog inputs
from a slave controller, use the SA command.

When using this command to access I/O on a slave controller in distributed control mode, use it with the handle for
outbound master commands. Do not use the handle which is for incoming slave update packets. For example, if a
slave is connected on handles E and F, reference the I/O for the slave on handle E.

ARGUMENTS: @AN [n]

where

n is an unsigned integer

USAGE:

EXAMPLES:

While Moving

Yes

Minimum n Value

1

In a Program

Yes

Maximum n Value

2

Not in a Program

Yes

Default n Value

n/a

Can be Interrogated

No

Default Format

10.4

Used as an Operand

Yes

Distributed Control

Use SA

#TEST

Program TEST

MG @AN[2]

Display the value of analog input #2 as a
voltage

JGX=@AN[2]*10000

Set jog speed according to analog input

SAA=”MG @AN[2]”

Sends command MG @AN[2] to slave on
handle A

Analog3=_SAA

Returns slave response to SA command

BGX

Begin Move

EN

End of program