184

LEGEND-MC User’s Manual

PN (Legend Parameter)

[Configuration]

DESCRIPTION:

The PN command sets or returns data residing in the Legend amplifier. The PN command causes the
controller to communicate to the amplifier via a serial connection on the mating connector. The available
parameter numbers are listed below. If the parameter was not accepted by the amplifier, a command error
will result. (TC=131 Amplifier Error) Paraemters that are successfully sent to the amplifier are stored in
EEPROM memory and effective immediately. This memory is separate from the controller memory, so
performing a master reset on the controller will not reset these values.

ARGUMENTS: PN p,v where

p is the parameter number, typically entered as a hex value, this is amplifier standard.

v is the value of the parameter, in the units required by the parameter.

USAGE:

OPERAND USAGE:

_PNp will return the value of the parameter where p is the parameter number.

RELATED COMMANDS:

ADDITIONAL INFORMATION

:

EXAMPLES:

While Moving

Yes

Default Value

n/a

In a Program

Yes

Default Format

hex

Command Line

Yes

Can be Interrogated

Yes

Used as an Operand

Yes

Distributed Control

Use SA

"TS" Tell

Switches

Parameter

Description

Default

Min

Max

$400

Maximum Torque Reference Gain
Input (mV)

10000

1000

10000

$401

Torque Reference Filter Frequency
(0.01 ms)

10

0

65535

$402

Forward Torque Limit (%)

800

0

800

$403

Negative Torque Limit (%)

800

0

800

$407

Speed Limit under torque control
(0.1%)

1000

0

1000

PN $400,2000

Set torque reference gain

MG _PN$407

Read Speed Limit