LEGEND-MC User’s Manual

Example:

Variable values may be assigned to controller parameters such as GN or PR. Here, an equal is not used.
For example:

PR V1

Assign V1 to PR command

Example - Using Variables for Joystick

The example below reads the voltage of an X-Y joystick and assigns it to variables VX and VY to drive
the motors at proportional velocities, where

10 Volts = 8191 counts --> 3000 rpm = 200000 c/sec

Speed/Analog input = 200000/8191 = 24.4

Internal Variables & Keywords

Internal variables allow motion or status parameters from LEGEND-MC commands to be incorporated
into programmable variables and expressions. Internal variables are designated by adding an underscore
(_) prior to the LEGEND-MC command. LEGEND-MC commands which can be used as internal
variables are listed in the Command Reference as "Used as an Operand".

Most LEGEND-MC commands can be used as internal variables. Status commands such as Tell Position
return actual values, whereas action commands such as GN or SP return the values in the LEGEND-MC
registers. The X,Y,Z or W or A,B,C,D,E,F,G,H for the LEGEND-MC, axis designation is required
following the command.

POSX=_TPX

Assigns returned value from TPX command to variable POSX.

SPEED=5.75

Assigns value 5.75 to variable SPEED

INPUT=@IN[2]

Assigns logical value of input 2 to variable INPUT

V2=V1+V3*V4

Assigns the value of V1 plus V3 times V4 to the variable V2.

VAR="CAT"

Assign the string, CAT, to VAR

#JOYSTICK

Label

JG 0,0

Set in Jog mode

BGXY

Begin Motion

#LOOP

Loop

VX=@AN[1]*24.4

Read joystick X

VY=@AN[2]*24.4

Read joystick Y

JG VX,VY

Jog at variable VX,VY

JP#LOOP

Repeat

EN

End