Advertising
background image

Brocade Mobility RFS Controller System Reference Guide

237

53-1003099-01

5

3. Select Advanced to expand its sub menu items.

4. Select MINT Protocol from the Advanced menu item.

FIGURE 118

Advanced Profile Overrides MINT screen - Settings tab

The Settings tab displays by default.

5. Refer to the Area Identifier field to define or override the Level 1 and Level 2 Area IDs used by

the profile’s MINT configuration.

6. Define or override the following Device Heartbeat Settings in respect to devices supported by

the profile:

7. Select the Latency of Routing Recalculation option (within the Shortest Path First (SPF) field) to

enable the spinner control used for defining or overriding a latency period (from 0 - 60
seconds). The default setting is disabled.

Level 1 Area ID

Select the box to enable a spinner control for setting the Level 1 Area ID (1 - 16,777,215). The
default value is disabled.

Designated IS Priority
Adjustment

Use the spinner control to set a Designated IS Priority Adjustment setting. This is the value added to
the base level DIS priority to influence the Designated IS (DIS) election. A value of +1 or greater
increases DISiness. The default setting is 0.