FIGURE 1

Fault Management Filter Events screen

Use the Filter Events screen to create filters for managing detected events. Events can be
filtered based on severity, module received, source MAC, device MAC and client MAC
address.

2. Define the following Customize Event Filters parameters for the Fault Management

configuration:

NOTE

Leave the fields to a default value of 00:00:00:00:00:00 to track all MAC addresses.

Severity

Set the filtering severity. Select from the following:
All Severities – All events are displayed, irrespective of their severity
Critical – Only critical events are displayed
Error – Only errors and above are displayed
Warning – Only warnings and above are displayed
Informational – Only informational and above events are displayed

Module

Select the module from which events are tracked. When a module is selected, events from other
modules are not tracked. Remember this when interested in events generated by a particular module.
Individual modules can be selected (such as TEST, LOG, FSM etc.) or all modules can be tracked by
selecting All Modules.

Source

Set the MAC address of the source device to be tracked. Setting a MAC address of 00:00:00:00:00:00
allows all devices to be tracked.

Message Substring

Optionally append a text message (substring) to the event filter to assist the administrator in
distinguishing this filter from others with similar attributes.