FIGURE 49

Wireless Controller - RAID Status screen

4. The Status field displays the following:

5. Refer to the Last Check field to assess the time, progress and results of the RAID array’s most

recent consistency check:

Size

Lists the size of the RAID drive array. The size is the total physical memory space available on the
two physical drives comprising the active RAID controller.

State

Displays whether the drive array is currently in an optimal operation state or degraded, and in need
of administration to perform diagnostics and perhaps prepare a standby drive for hot spare
replacement.

Alarm Enable

Displays whether the RAID alarm has been enabled to sound the service platform’s chassis alarm
upon detection of a RAID controller degradation event. The RAID alarm is enabled by default. For
information on enabling or disabling the service platform RAID alarm, see General Profile
Configuration on page 8-380
.

Date

Lists the date and time of the RAID controller’s most recent consistency check on the integrity of
the drive array.

Result

Displays true for a successful RAID array consistency check and false for a failed consistency
check. A false indication would trigger the service platform’s chassis alarm if RAID alarm is
enabled.

Progress

Displays the progress of an in process consistency check in both percentage complete and minutes
utilized (for example, 78%/116min).