1 components used, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 102

Advertising
background image

PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

9400 HighLine - "LAS_40_INTF_Can_94HL_TabPos" sample project

102

L

1.3 EN - 07/2012

8.4

9400 HighLine - "LAS_40_INTF_Can_94HL_TabPos" sample project

Further information on the function libraries used in this project can be found in

the following section:



The L_S94_Drive9400.lib library

( 246)

Standard procedure

How to commission the controller:

1. Commission the 9400 HighLine.
2. Load the project "LAS_40_INTF_Can_94HL_TabPos.zip" to the controller using the

L-force »Engineer«.



Open the »Engineer« project & go online

( 104)

3. Open the "LAS_40_INTF_Can_94HL_TabPos.pro" sample project in the »PLC

Designer«.



Program structure in the »PLC Designer«

( 106)

4. Load the project to the IPC/EL 1xx and go online.

8.4.1

Components used

[8-20] System configuration with EL x800 CAN master (ID=0, connection at CAN1) and 9400 HighLine (CAN node ID=5)

Industrial PC

Field device

Hardware

EL x800

9400 HighLine

Operating system

IPC software from version Logic

7.02.x (release 2.2.x)

From firmware V7.0

Lenze software required

»PLC Designer« from version 20.3

L-force »Engineer« from version 2.12

Further requirements

• CAN master ID = 0

• Connection at interface CAN1

• Logic CAN 500kB

• CAN node ID = 5

• Motor: MCS06C41

Advertising