PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

9300 - "LAS_40_INTF_Can_93_EP" sample project

204

L

1.3 EN - 07/2012

8.8.5.5

Homing mode

Button  selects the homing mode.

Note!
• The homing is only to be carried out once after initial switch-on.
• The reference can not be reset.
• Program set number 3 in manual mode activates the reference setting.

– As a standard setting, homing mode 0 is active in the controller (travel over ref-mark

/ DigIn 4 in positive direction with H-L edge negative to home position)

Button  starts the homing.

Button  stops homing.

Button sets the home position.
– Set direct reference / Pos Act = 0 unit

Dialog box  shows the homing status.

Dialog box  signalises whether the homing has been completed successfully.
– After a successful homing, the display field is coloured in green.

Dialog box  shows the current homing mode (code value).

Select mode

Stop button



Reset position



Start button

Set position

Mode status