2 special features of the 8400 inverter drives, 3 commission 8200 vector frequency inverters, 4 special features of the ecs servo system – Lenze PLC Designer V2.x User Manual

Page 32: Plc designer v2.x| lenze application samples

Advertising
background image

PLC Designer V2.x| Lenze Application Samples

Commissioning the CANopen Logic bus

Preparing the restart

32

L

1.3 EN - 07/2012

6.3.2

Special features of the 8400 Inverter Drives

Inverter Drives 8400 are purely parameterisable devices.
To put an Inverter Drive 8400 into operation, you can transmit the application using the

»Engineer«. For this, you must keep the original »Engineer« project.

6.3.3

Commission 8200 vector frequency inverters

Connect the CANopen (E82ZAFUCxxx) fieldbus function module for CAN

communication.

CAN settings must be made in the »PLC Designer« because the transmission of the

settings to the 8200 vector frequency inverter is carried out from the control system.

6.3.4

Special features of the ECS servo system

In the ECS servo system, each device has a parameter memory which is only created

once when the parameter setting is created via the »Global Drive Control«. This is the

difference to CANopen devices where the parameterisation is written into the field

device at each system start.

The EMF2221IB card module serves to read parameters saved on an SD card or

SmartMedia card into every ECS device.

When using ECS devices, you cannot set all codes/parameters via the Service Data

Objects tab as the EDS files do not contain all codes/parameters.

Advertising