Structure of, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 281

Advertising
background image

1.3 EN - 07/2012

L

281

PLC Designer V2.x| Lenze Application Samples

The L_S93_Drive9300.lib library

L_S93_Positioning - control the 9300 Positioning

16.2.2

Structure of S93_DriveStatus_93xxEP - status of the 9300 EP controller

The bit assignment in the software application is identical to the bit assignment in the

controller.
Further information on the interface assignments can be found in the following section:



Interface assignment in the »Global Drive Control«

( 185)

Identifier/data type

Control bits in the controller

Bit

Identifier

Meaning

xPosBusy

BOOL

0

STAT.B0

Profile positioning is active

xImp

BOOL

1

DCTRL-IMP

Pulse inhibit

xQSPActive

BOOL

2

STAT.B2

Activate quick stop

xDriveError

BOOL

3

STAT.B3

Status for error in the controller

TRUE: Error in the controller reported

FALSE: No error reported

xRefOk

BOOL

4

STAT.B4

Home position available

xInTarget

BOOL

5

STAT.B5

1 = The actual position is in the target

window (C3034) around the target position

(message: Target position reached)

xNactEqZero

BOOL

6

DCTRL-NACT=0

TRUE: Speed is zero

xEnabled

BOOL

7

DCTRL-CINH

Enable controller

xStat_1

BOOL

8

DCTRL-STAT*1

Not assigned

xStat_2

BOOL

9

DCTRL-STAT*2

Not assigned

xStat_4

BOOL

10

DCTRL_STAT*4

Not assigned

xStat_8

BOOL

11

DCTRL_STAT*8

Not assigned

xWarning

BOOL

12

DCTRL-WARN

TRUE: Warning active

xMessage

BOOL

13

DCTRL-MESS

TRUE: Message active

xFreeBit14

BOOL

14

STAT.B14

Not assigned

xReady

BOOL

15

STAT.B15

Status signal "Controller is ready for

operation"

rNact

Actual speed value

rActPos

Current position

Advertising