3 what to do if the motor does not rotate – Lenze PLC Designer V2.x User Manual

Page 233

Advertising
background image

1.3 EN - 07/2012

L

233

PLC Designer V2.x| Lenze Application Samples

Diagnostics

What to do if the CAN bus is not running/CAN nodes do not respond?

10.2

What to do if the CAN bus is not running/CAN nodes do not respond?

By default the baud rate of the devices is set to 500K.

The CAN bus address (node ID) is set to 1 by default.

How to check the settings of CAN communication:

1. Check the CAN master settings of the EL100 or for the IPC/CPC in the »PLC

Designer«.



Configuring the CAN interface

( 35)

2. Check the wiring of the CAN bus cable (in the case of an individual cable, check the

terminal assignment) with the CAN nodes.



Wiring the hardware

( 34)

3. Check the setting of the DIP switches on the controllers.
4. Check the assignment of the terminating resistors (120 Ohm at the start and the

end of the bus, respectively).

5. Check the status information in the CAN diagnostics of the project.
6. Check the CAN status in the CAN nodes using the »Engineer« or »Global Drive

Control«.
Note: The CAN nodes have to be in the "Operational" status (see drive-specific

parameters).

7. Reset CAN node at the controller.

10.3

What to do if the motor does not rotate?

If the CAN bus is ready for operation and CAN communication works faultlessly, by

means of the drive-specific »Global Drive Control« or »Engineer« software it can be

checked whether the setpoint transmitted by the CAN master is accepted.

Check whether...

1. ...the digital inputs of the controllers for the loaded application are in the correct

position, and the suitable voltage level is applied.

2. ...the controller is enabled, CINH = 1 (TRUE).

Note!

Within a CAN bus line never two identical addresses must be used.
• In the sample project the addresses for the CAN nodes are already fixedly

entered or assigned.

Further information on the communication parameter settings can be found in

the documentation for the corresponding controller.