The L_SSC_Scaling.lib library

L_SSC_UnitToAcc - conversion block (for 9400 device series)

330

L

1.3 EN - 07/2012

20.20

L_SSC_UnitToAcc - conversion block (for 9400 device series)

This FB converts an acceleration value specified in the real unit of the machine to an

internal acceleration value on the basis of the machine parameters transmitted.

Inputs

Outputs

Identifier/data type

Information/possible settings

diAccIn_e4

DINT

Acceleration in unit/s2]

Selection in "e4" view (fixed point with four decimal positions)

scAxisData

SSC_Axis_logic

Machine parameters

Identifier/data type

Information/possible settings

diAccOut_x

DINT

Acceleration as speed variation/time in [rpm/s]

15000000 rpm/s ≡ 2

22

= 4194304

xLimit

BOOL

"Output signal is limited" status

• TRUE: The output signal is limited to the representable value range

±214748.3647.

xError

BOOL

"Error" status signal

FALSE Conversion carried out without errors

TRUE Error during the conversion