The L_SCS_DriveECS.lib library

L_SCS_SupplyModule - actuation of the ECS servo system power supply module

264

L

1.3 EN - 07/2012

13.4.1

Structure of SCS_Control_Supply - actuation to the ECS controller power supply module

Further information on the internal interfaces of the controller can be found in

the Operating instructions (BA) ECSxE_power supply module:
• Section Configuration

Configure system bus | Assignment of the control word

Identifier/data type

Control bits in the

controller

Bit

Identifier

Meaning

xToggleBit

BOOL

0

STE_TOGGLE

Toggle bit

• Bit state change as a sign of life of the

control

xErrorReset

BYTE

1

STE_RESET

TRUE: Reset error

xActivateKSB

BOOL

2

STE_KSB

TRUE: Execute short-circuit braking

xEnableAxis

BOOL

3

STE_CONTROLLE

R ENABLE

TRUE: X6/DO1 is HIGH when the power

supply module is ready for operation

and input X6/DI2 is HIGH.