The L_SSC_Scaling.lib library

L_SSC_SpeedToUnit - conversion block (for 9400 device series)

20.18

L_SSC_SpeedToUnit - conversion block (for 9400 device series)

This FB converts a speed value specified in the internal unit [rpm] to a speed value in the

real unit of the machine on the basis of the machine parameters transmitted.

Inputs

Outputs

20.19

L_SSC_TaskCycle - read in task time

This function determines the cycle time of the task.

Output signal

Identifier/data type

Information/possible settings

diSpeedIn_s

DINT

Velocity as speed in [rpm] 15000 rpm ≡ 2

26

= 67108864

scAxisData

SSC_Axis_logic

Machine parameters

Identifier/data type

Value/meaning

diSpeedOut_e4

DINT

Speed in [unit/s]

• Display in "e4" view (fixed point with four decimal positions)

xLimit

BOOL

"Output signal is limited" status

• TRUE: The output signal is limited to the representable value range

±214748.3647.

xError

BOOL

"Error" status signal

FALSE Conversion carried out without errors

TRUE Error during the conversion

Identifier/data type

Value/meaning

diOut_s

TIME

Task time in [ms]