The L_SCS_DriveECS.lib library

L_SCS_SupplyModule - actuation of the ECS servo system power supply module

13.4.2

Structure of SCS_Status_Supply - status of the controller

Further information on the internal interfaces of the controller can be found in

the Operating instructions (BA) ECSxE_power supply module:
• Section Configuration

Configure system bus | Assignment of the status words

Identifier/data type

Control bits in the

controller

Bit

Identifier

Meaning

xBTB_ReadyForOperation

BOOL

0

STA1_BTB

TRUE: Power supply module ready

xWarning

BOOL

1

STA1_

WARNING

TRUE: Warning active

xMessage

BOOL

2

STA1_MESSAGE

TRUE: Message active

xTrip

BOOL

3

STA1_TRIP

Status message

TRUE: Error message active

xKSB_FAIL

BOOL

4

STA1_KSB_FAIL

TRUE: No short-circuit braking possible,

since the DC bus is loaded externally.

xKSB_Active

BOOL

5

STA1_KSB_ACTIV

E

1 = Pulse inhibit (DCTRL-IMP) active,

inverter inhibited

xK1_Active

BOOL

6

STA1_K1_ON

TRUE: No short-circuit braking possible,

since the DC bus is loaded externally.

xK2_Active

BOOL

7

STA1_K2_ON

TRUE: Short-circuit braking active

xDI1

BOOL

11

STA1_DI1

1 = The actual position is in the target

window (C3034) around the target

position

(message: Target position reached)

xDI2

BOOL

12

STA1_DI2

1 = The dwell time (C3035) has expired.

Note: Bit is reset to "0" when positioning

is started.

xToggleBit

BOOL

13

STA1_TOGGLE

Toggle bit

xFreeBit14

BOOL

14

free

Not assigned

xFreeBit15

BOOL

15

free

Not assigned

eErrorCode

SCS_ErrorCode

Reset error