PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

9300 - "LAS_40_INTF_Can_93_EP" sample project

200

L

1.3 EN - 07/2012

Further information on the FB can be found in the following section:



Structure of

S93_DriveControl_93xxEP - actuation to the 9300 EP controller

( 280)

Area  visualises the FB for reading out the errors from the controller.

Further information on the FB can be found in the following section:



L_S93_ReadErrorCode - read out error status

( 282)

Mode/profile

Meaning

Homing

byProfileNumber = 2 Start homing

Positioning

byProfileNumber = 4 or 5

byProfileNumber = 7

Start positioning

Direct positioning with the set position "iSetPos". The positioning range is

limited to +/- 32767.

• Via the "xErrorSet" button, an external error is triggered.

• Via the "xErrorReset" button, the error can be reset.

Speed

byProfileNumber = 6 Start speed operation

• The controller approaches the setpoint "rNset" in a speed-controlled

manner.