3 manual mode ("manual jog"), Manual mode ("manual jog"), Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 157

Advertising
background image

1.3 EN - 07/2012

L

157

PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

8200 vector - "LAS_40_INTF_Can_82_Speed" sample project

8.6.5.3

Manual mode ("Manual jog")
Via the visualisation of block L_S8V_ActuatorSpeed, the 8200 vector can be controlled in

manual operation. The current error can be read out via the visualisation of block

L_S8V_ReadErrorCode.

Button  selects the manual (manual jog) mode.

In the control and status panel  the FB for controlling the 8400 Stateline is visualised.
Note: The xQsp button (quick stop) must not be activated!
Enable the controller via FB input xEnable to activate the manual mode. Afterwards the

controller can be actuated via the visualisation in manual operation.
– Via rNSet the speed in [%] can be defined
– A fixed speed can be specified via xJog1 and xJog2.
Via the xErrorSet button, an external error is triggered.
Via the xErrorReset button, the error can be reset.

Further information on the FB can be found in the following section:



L_S8V_ActuatorSpeed - actuation of the 8200 vector controller

( 267)

Area  visualises the FB for reading out the errors from the controller.

Further information on the FB can be found in the following section:



L_S8V_ReadErrorCode - read out error status

( 270)

Select mode

Reading out an

error



Control/status panel

Advertising