The L_S8V_Drive82Vector.lib library

L_S8V_ActuatorSpeed - actuation of the 8200 vector controller

14

The L_S8V_Drive82Vector.lib library

This chapter describes the function blocks of the L_S8V_Drive82Vector function library.

The function blocks of this function library serve to parameterise the 8200 vector Lenze

frequency inverter.

14.1

L_S8V_ActuatorSpeed - actuation of the 8200 vector controller

This FB serves as a control block for the 8200 vector.

Inputs

Outputs

Further information on the controller can be found in the following

documentation:
System manual (SHB) 8200 vector - Global Drive

Identifier/data type

Information/possible settings

scDriveControl

Structural data for drive control

xOptional

BOOL

Optional setting for the CAN node

FALSE Normal operation (transmission and reception via PDO)

TRUE The CAN node is set to the "Optional" mode to be able to receive

PDOs.

byNodeNumber

BYTE

Node number

byMasterNumber

BYTE

Interface number (0...3)

Identifier/data type

Information/possible settings

scDriveStatus

Structural data regarding the drive status

xInternalControlActiv

BOOL

TRUE: Internal control active