PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

8200 vector - "LAS_40_INTF_Can_82_Speed" sample project

166

L

1.3 EN - 07/2012

[8-35] Assignment of CAN-Out 1

The CAN monitorings are activated in the project: monitoring time of 3000 ms, "error"

response in the controller.

[8-36] Parameterisation of the 8200 vector in the »Global Drive Control«: Example of setting a "Trip" (C0126) in the controller

The following bits of STAT are assigned

and connected on CAN-OUT1:
bState_B00 = free
bState_B01 = not used
bState_B02 = xQSPActive
bState_B03 = xDriveError
bState_B04 = free
bState_B05 = free
bState_B06 = xSpeedEqZero
bState_B07 = xEnable
bState_B08 = free
bState_B09 = free
bState_B10 = free
bState_B11 = free
bState_B12 = not used
bState_B13 = free
bState_B14 = not used
bState_B15 = xDriveReady

Advertising