The L_SCS_DriveECS.lib library

L_SCS_ActuatorSpeed - actuation of the ECS servo system

13.1.2

Structure of SCS_DriveStatus_Speed - status of the controller

Further information on the internal interfaces of the controller can be found in

the Operating instructions (BA) ECSxS_axis module_Speed_and_Torque:
• Section Function library

DCTRL

| Status of the controller

Identifier/data type

Control bits in the

controller

Bit

Identifier

Meaning

xDriveReady

BOOL

0

DCTRL-StatB0

Status signal "Controller is ready for

operation"

xDriveEnabled

BOOL

1

Imp

TRUE: Controller active

xQSPActive

BOOL

2

DCTRL-StatB2

Activate quick stop

xDriveError

BOOL

3

DCTRL-StatB3

Status for error in the controller

TRUE: Error in the controller reported

FALSE: No error reported

xFreeBit04

BOOL

4

DCTRL-StatB4

Not assigned

xFreeBit05

BOOL

5

DCTRL-StatB5

Not assigned

xSpeedEqZero

BOOL

6

NActEq0

TRUE: Speed is zero

xFreeBit07

BOOL

7

CInh

Not assigned

xFreeBit08

BOOL

8

Stat1

Not assigned

xFreeBit08

BOOL

9

Stat2

Not assigned

xFreeBit10

BOOL

10

Stat4

Not assigned

xFreeBit11

BOOL

11

Stat8

Not assigned

xFreeBit12

BOOL

12

Warn

Not assigned

xFreeBit013

BOOL

13

Mess

Not assigned

xFreeBit14

BOOL

14

DCTRL-StatB14

Not assigned

xFreeBit15

BOOL

15

DCTRL-StatB15

Not assigned

rNset

REAL

Speed-

MCTRL.NSetIn

Actual speed value