Components used

[8-14] System configuration with EL x800 CAN master (ID=0, connection at CAN1) and 9400 HighLine (CAN node ID=5)

8.3.2

Short overview of the functions

Industrial PC

Field device

Hardware

EL x800

9400 HighLine

Operating system

IPC software from version Logic

7.02.x (release 2.2.x)

From firmware V7.0

Lenze software required

»PLC Designer« from version 20.3

L-force »Engineer« from version 2.12

Further requirements

• CAN master ID = 0

• Connection at interface CAN1

• Logic CAN 500kB

• CAN node ID = 5

• Motor: SDSGAI056-22

Mode

Description

Automatic

In the automatic mode a sequence runs over an infinite loop.

Selection:

• Travel for three seconds at speed1,

• then for five seconds at speed2,

• Start with speed1 again.

Manual

In manual mode, the controller can be actuated by setting the individual

control bits manually (Jog1, Jog2, QSP, ErrorReset...). Like this, the controller

can be actuated in manual mode, for instance for cleaning or changing the

tools.

Service

The service mode serves to adjust the controller.

Selection:

• Travel in positive direction for one second,

• Stop for one second,

• Travel in negative direction for one second.