3 manual mode ("manual jog"), Manual mode ("manual jog"), Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 199

Advertising
background image

1.3 EN - 07/2012

L

199

PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

9300 - "LAS_40_INTF_Can_93_EP" sample project

8.8.5.3

Manual mode ("Manual jog")
The 9300 EP can be controlled in manual operation via the visualisation of block

L_S93_Positioning. Via the visualisation of block L_S93ReadErrorCode the current error

can be read out.

Button  selects the manual (manual jog) mode.

In the control and status panel  the FB for actuating the controller is visualised.
byFuncNumber serves to display different status data in iPar1 and iPar2.

Via the visualisation of the L_S93_Positioning block, the 9300 EP can be controlled in

manual operation.
Note:
The xQsp button must not be activated.
Enable the controller via FB input xEnable to activate the manual mode. Afterwards the

controller can be actuated via the visualisation in manual operation.

The controller can be actuated via the buttons xManualPos and xManualNeg within the

software limitation C1224 (position limit negative) -214000 units / C1223 (position

limit positive) 214000 units.

If the limit values are exceeded or not reached, an error is triggered.

After the error acknowledgement, the controller can be traversed in the opposite

direction.
All other functions can be activated via profiles:

Select mode

Reading out an

error



Control/status panel

Advertising