3 manual mode ("manual jog"), Manual mode ("manual jog"), Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 71

Advertising
background image

1.3 EN - 07/2012

L

71

PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

8400 HighLine - "LAS_40_INTF_Can_84HL_TabPos" sample project

8.2.5.3

Manual mode ("Manual jog")
The 8400 StateLine can be controlled by means of the visualisation of block

L_S84_TablePositioningHL in manual operation. Via the visualisation of block

L_S84ReadErrorCode the current error can be read out.

Button  selects the manual (manual jog) mode.

In the control and status panel  the FB for controlling the 8400 Stateline is visualised.

By means of the visualisation of block L_S84_TablePositioningHL, the 8400 HighLine

can be operated in manual operation (byProfilenumber = 2).
Note: Enable the controller via FB input xEnable to activate manual mode. The

controller can then be actuated via the visualisation in manual operation. The xQsp

button must be activated so that quick stop is activated.

Further information on the FB can be found in the following section:



L_S84_TablePositioningHL - profile data record management

( 243)

Area  visualises the FB for reading out the errors from the controller.

Further information on the FB can be found in the following section:



L_S84_ReadErrorCode - read out error status

( 241)

Select mode

Reading out an

error



Control/status panel

Profile number

Function

byProfileNumber = 1

Homing

byProfileNumber = 2

Manual jog

byProfileNumber = 3 or 4

Positioning