1 scb_statecanmaster, 2 structure of scb_cannodediagnose, L_scb_sdo_transfertable - transfer parameter list – Lenze PLC Designer V2.x User Manual

Page 299: Plc designer v2.x| lenze application samples

Advertising
background image

1.3 EN - 07/2012

L

299

PLC Designer V2.x| Lenze Application Samples

The L_SCB_CANBasic.lib library

L_SCB_SDO_TransferTable - transfer parameter list

17.18.1

SCB_StateCanMaster

CanMaster_NotInHardWareCatalogus:=-1,
CanMaster_Init0 := 0,
CanMaster_Init1 := 1,
CanMaster_Init2 := 2,
CanMaster_SDO_Config := 3,
CanMaster_Init4 := 4,
CanMaster_Operational := 5

17.18.2

Structure of SCB_CanNodeDiagnose -

17.19

L_SCB_SDO_TransferTable - transfer parameter list

This FB serves to write or read a parameter list.

Inputs

Identifier/data type

Information/possible settings

iState

SCB_StateCanNode

Status enquiry of CAN node

byNodeID

BYTE

Node number (0...3)

byMasterID

BYTE

Interface number (ID)

xCommunicationOK

BOOL



L_SCB_GetNodeDataRxPDO1 - read out data ( 285)



L_SCB_GetNodeDataRxPDO2 - read out data ( 286)

Identifier/data type

Information/possible settings

xExecute

BOOL

Trigger read request.

TRUE Cycle time (dwCycleTime) = "0 ms" or input dwCycleTime

Not assigned:

Read parameter value once, which was addressed via the inputs

dwCode,

dwSubcode, dwComChannel, and dwTargetAddress.

FALSE Deactivate cyclic reading.