4 program structure in the »plc designer, 1 control configuration, Control configuration – Lenze PLC Designer V2.x User Manual

Page 193: Program structure in the »plc designer

Advertising
background image

1.3 EN - 07/2012

L

193

PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

9300 - "LAS_40_INTF_Can_93_EP" sample project

8.8.4

Program structure in the »PLC Designer«

How to proceed:

1. In the »PLC Designer«, open the "LAS_40_INTF_Can_93_EP.pro" sample project.
2. Load the project to the IPC and Go online.

8.8.4.1

Control configuration

The CAN master (ID = 0) is the control section of the system configuration

Below the CAN master the 9300 EP (CAN node ID = 5) is attached.
– The 9300 EP is embedded in the form of a device-independent EDS file

(LenzeDrive_Can1_4Word).

One PDO each is used for CAN-Input and CAN-Output.

The transmission mode is sync-controlled (10 ms).

Advertising