15 the l_s8s_drive82smd.lib library, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 272

Advertising
background image

PLC Designer V2.x| Lenze Application Samples

The L_S8S_Drive82SMD.lib library

L_S8S_ActuatorSpeed - actuation of the 8400 SMD controller

272

L

1.3 EN - 07/2012

15

The L_S8S_Drive82SMD.lib library

This chapter describes the function blocks of the L_S8S_Drive82SMD. function library. The

function blocks of this function library serve to parameterise the 8200 SMD Lenze

frequency inverter.

15.1

L_S8S_ActuatorSpeed - actuation of the 8400 SMD controller

This FB serves to actuate the 8400 SMD controller.

Inputs

Outputs

Further information on the internal interfaces of the controller can be found in

the Operating Instructions (BA)_ESMD_CAN-Frequency_Inverter for the 8200

SMD:
• Section CANopen | Detailed assignments

Identifier/data type

Information/possible settings

xOptional

BOOL

Optional setting for the CAN node

FALSE Normal operation (transmission and reception via PDO)

TRUE The CAN node is set to the "Optional" mode to be able to receive

PDOs.

byNodeNumber

BYTE

Node number

byMasterNumber

BYTE

Interface number (1 ... 4)

Identifier/data type

Information/possible settings

scDriveStatus

Structural data regarding the drive status

xInternalControlActiv

BOOL

TRUE: Internal control active

Advertising