3 l_ssc_getposition - conversion block, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 318

Advertising
background image

PLC Designer V2.x| Lenze Application Samples

The L_SSC_Scaling.lib library

L_SSC_GetPosition - conversion block

318

L

1.3 EN - 07/2012

20.3

L_SSC_GetPosition - conversion block

This FB converts the input signal transmitted to a position signal.

Inputs

Outputs

Identifier/data type

Information/possible settings

diPosIn_p

DINT

Position in [increments]

Scaling: 1 encoder revolution ≡ 2

16

increments (or according to scAxisData)

scAxisData

SSC_Axis_logic

Machine parameters

Identifier/data type

Information/possible settings

rPositionOutUnits

REAL

Position value

Display of the input signal dnPosIn_p in the real unit of the machine.

xError

BOOL

"Error" status signal

FALSE Conversion carried out without errors

TRUE Error during the conversion