12 the l_s94_drive9400.lib library, The l_s94_drive9400.lib library, Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 246

Advertising
background image

PLC Designer V2.x| Lenze Application Samples

The L_S94_Drive9400.lib library

L_S94_ActuatorSpeed - actuation of the 9400 HighLine controller

246

L

1.3 EN - 07/2012

12

The L_S94_Drive9400.lib library

This chapter describes the function blocks of the L_S94_Drive9400 function library. The

function blocks of this function library serve to parameterise the Lenze Servo Drive 9400.

12.1

L_S94_ActuatorSpeed - actuation of the 9400 HighLine controller

This FB serves to control the 9400 Highline with the "Speed control" application.

Inputs

Outputs

Further information on the controller can be found in the following

documentation:
Software manual (SW) 9400 HighLine controller - Parameter setting &

Configuration

Software manual (SW) 9400 controller - "Table positioning" technology

application

Identifier/data type

Information/possible settings

scDriveControl

S94_DriveControl_ActSpeed

Structural data for drive control

xOptional

BOOL

Optional setting for the CAN node

• TRUE: The CAN node is set to the "Optional" mode to be able to receive PDOs.

• FALSE: Normal operation (transmission and reception via PDO).

byNodeNumber

BYTE

Node number

byMasterNumber

BYTE

Interface number (0...3)

Identifier/data type

Information/possible settings

scDriveStatus:S94_DriveStat

us_ActSpeed

Structural data for drive control

xInternalControlActive

BOOL

TRUE: Internal control active

Advertising