3 manual mode ("manual jog"), Manual mode ("manual jog"), Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 177

Advertising
background image

1.3 EN - 07/2012

L

177

PLC Designer V2.x| Lenze Application Samples

Working with the sample projects

9300 servo - "LAS_40_INTF_Can_93_Speed" sample project

8.7.5.3

Manual mode ("Manual jog")
The 9300 ES can be controlled in manual operation via the visualisation of block

L_S93_ActuatorSpeed. Via the visualisation of block L_S93ReadErrorCode the current

error can be read out.

Button  selects the manual (manual jog) mode.

In the control and status panel  the FB for controlling the 9300 is visualised.
Note: The xQsp button (quick stop) must not be activated!
Enable the controller via FB input xEnable to activate the manual mode. Afterwards the

controller can be actuated via the visualisation in manual operation.
– Via rNSet the speed in [%] can be defined
– A fixed speed can be specified via xJog1 and xJog2.
Via the xErrorSet button, an external error is triggered.
Via the xErrorReset button, the error can be reset.

Further information on the FB can be found in the following section:



Structure of

93_DriveControl_Speed - actuation to the controller

( 277)

Area  visualises the FB for reading out the errors from the controller.

Further information on the FB can be found in the following section:



L_S93_ReadErrorCode - read out error status

( 282)

Select mode

Reading out an

error



Control/status panel

Advertising