Plc designer v2.x| lenze application samples – Lenze PLC Designer V2.x User Manual

Page 245

Advertising
background image

1.3 EN - 07/2012

L

245

PLC Designer V2.x| Lenze Application Samples

The L_S84_Drive8400.lib library

L_S84_TablePositioningHL - profile data record management

11.6.2

Structure of S84_DriveStatus_8400HL_TablePositioning - status of the controller

Identifier/data type

Control bits in the controller

Bit

Identifier

Meaning

xDriveError

BOOL

0

bDriveFail

Controller is in error status (TRUE: Error

active)

xStateBit1

BOOL

1

bGPSignalOut1

Binary signal monitor: Output signals

xStateBit2

BOOL

2

bGPSignalOut2

xDriveEnabled

BOOL

3

bCInhActive

Controller inhibit is active

xDriveReady

BOOL

4

bDriveReady

Status signal "Controller is ready for

operation"

xDigin5

BOOL

5

DigitalInput.bIn5

Signal of digital input DI5 ... DI7

xDigin6

BOOL

6

DigitalInput.bIn6

xDigin7

BOOL

7

DigitalInput.bIn7

xPosInTarget

BOOL

8

bInTarget

Target position (actual value) is in the target

window

xPosBusy

BOOL

9

bProfileBusy

Profile positioning is active

xHomePosAvailable

BOOL

10

bHomePosAvailable

Home position is known

xSpeedEqZero

11

bSpeedActCompare

Result of the speed comparison

xDigin3_LimitSwPositive

13

DigitalInput.bIn3

Digital input 3

xDigin4_LimitSwNegative

12

DigitalInput.bIn4

Digital input 4

xQSPActive

BOOL

14

bQSPIsActive

Quick stop is active

xStateBit15

BOOL

15

Not assigned

Not assigned

rActualSpeed

REAL

nMotorSpeedAct_a

Actual speed value

xCommunicationOK

BOOL



L_SCB_GetNodeDataRxPDO1 - read out data ( 285)



L_SCB_GetNodeDataRxPDO2 - read out data ( 286)

xOptional

BOOL



L_SCB_GetStateOptional - check with regard to "OptionalDevice" ( 287)

eCanNodeState

SCB_StateCanNode

rActualPosition

REAL

Current position

Advertising