The L_S94_Drive9400.lib library

L_S94_TablePositioning - table positioning

12.4

L_S94_TablePositioning - table positioning

This FB serves to control the 9400 Highline with the "Table positioning" application.

Inputs

Outputs

Identifier/data type

Information/possible settings

scDriveControl

S94_DriveControl_TablePosi

tioning

Structural data for drive control

Table positioning

scAxisData

SSC_Axis_logic

Machine parameters

• For the calculation and display of the reference values on the load side (output

shaft

speed, machine speed), the reference speed (C00011), gearbox

factor, and the feed constant are required.

• In order that the machine parameters of the drive/motor are accepted, connect this

input with the output DI_AxisData of SB LS_DriveInterface.

xOptional

BOOL

Optional setting for the CAN node

• TRUE: The CAN node is set to the "Optional" mode to be able to receive PDOs.

• FALSE: Normal operation (transmission and reception via PDO).

byNodeNumber

BYTE

Node number

byMasterNumber

BYTE

Interface number (0...3)

Identifier/data type

Information/possible settings

scDriveStatus

S94_DriveStatus_TablePositi

oning

Structural data regarding the status of the controller

Table positioning

xInternalControlActive

BOOL

TRUE: Internal control active