Commissioning – Lenze ECSCAxxx User Manual

Page 105

Advertising
background image

Commissioning

Carrying out basic settings with GDC

6

l

105

EDBCSXA064 EN 3.2

Detailed

information

Brief description

Settings

10. Set the polarity of the digital

inputs and outputs.

Select Terminal I/O

W Digital inputs/outputs in the GDC

parameter menu:

l

C0114/x (polarity of dig. inputs X6/DI1 ... DI4)

l

C0118/1 (polarity of dig. output X6/DO1)

^ 129

11. Enter machine parameters.

Set machine parameters as for instance maximum speed
and ramp times in the parameter menu under Short
setup

W Motor setting .

^ 130

12. Switch on the mains.

l

Green LED is blinking and red LED is off:
– Controller is ready for operation.

l

Green LED is off and red LED is blinking:
– An error has occurred. Eliminate the error before you

continue commissioning.

The basic settings are completed now.

Proceed as follows:

ƒ

Enable controller (

^ 131).

ƒ

Save parameters in the controller with C0003 = 1.

ƒ

Save parameter set with GDC in the parameter set file.

ƒ

Optimise drive behaviour (

^ 141).

Advertising