Code table

14

l

413

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0593 MONIT CE3

3

Fault response − monitoring
CAN3_IN (no telegrams)
"CommErrCANIN3" (CE3)

^ 202

0

TRIP

2

Warning

3

Off

C0594 MONIT SD6

3

Fault response − monitoring
KTY sensor for the motor
temperature.
"SensorFault" (Sd6)

^ 223

0

TRIP

2

Warning

3

Off

C0595 MONIT CE4

3

Fault response − system bus
(CAN) monitoring "Bus−off" at X4
"BusOffState" (CE4)

^ 202

0

TRIP

2

Warning

3

Off

C0596 NMAX limit

5500

Maximum system speed

^ 227

0

{1 rpm}

16000

C0597 MONIT LP1

3

Fault response − monitoring of
motor phase failure (LP1)
When this function is activated,
the calculating time provided for
the user program is reduced!

^ 221

0

TRIP

2

Warning

3

Off

C0598 MONIT SD5

3

Fault response − master current
monitoring at X6 < 2 mA
"MastISourceDef"

^ 275

0

TRIP

2

Warning

3

Off

C0599 Limit LP1

5.0

Monitoring limit for motor phase
failure monitoring (LP1) with
regard to the current limit.

^ 221

0.01

{0.01 %}

10.00

C0602 MONIT REL1

3

Fault response − open circuit
monitoring of relay output X25

0

TRIP

2

Message

3

Off

4

FAIL−QSP