Appendix

Memories

Download of various data items

14

l

379

EDBCSXA064 EN 3.2

14.3.3

Download of various data items

In DDS (as of version 2.0) it is possible to attach a file to your project whose data are
automatically transferred in the drive controller when the program is downloaded.

ƒ

This mechanism is, for instance, used in the software package "Cam" to download
motion profiles.

)

Note!

With regard to the ECSxA... axis module, the additional data is immediately
attached to the PLC program, because the module is not provided with an
application memory (FLASH).

Data will be downloaded if the following conditions are met:

1. The PLC program in the ECSxA... axis module has to be stopped.

2. The header of the file attached to the project must have the following structure:

Name

Data type

Data length in bytes Content

wSizeHeader

WORD

2

Header length in bytes

wDataType

WORD

2

Data specification identifier

l

This information can be found under C2131 after
data has been downloaded.

0 ... 10000 Lenze−specific data

> 10000 User data

dwVersion

DWORD

4

Data version

l

This information can be found under C2132 after
data has been downloaded.

dwRealSize

DWORD

4

User data length in bytes (without header)

dwTimeStamp

DWORD

4

Time stamp of the last data change

l

This information can be found under C2133 after
data has been downloaded.

wLicenseInfo

WORD

2

Reserved for future extensions

wSizeSymbolicName

WORD

2

Length of the symbolic file name

achSymbolicName

ACH

wSizeSymbolicName Character array including the symbolic file name

l

This information can be found under C2130 after
data has been downloaded.

wCopyToRam

WORD

2

Specifying whether the data is automatically copied
into the application RAM of the ECSxA... axis module
after download.

l

Maximum data length = 128 kbytes (RAM block 1
& 2)

0 Data is not copied into the application

RAM.

1 Data is copied into the application RAM.

2 ... 65535 Reserved

dwReserved

DWORD

4

Reserved for future extensions

awSizeAddInfo

DWORD

190

Interpretation of the header information: least significant byte first.