13 adjusting the motor data, System modules – Lenze ECSCAxxx User Manual

Page 366

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)
Adjusting the motor data

13

l

366

EDBCSXA064 EN 3.2

13.20.13

Adjusting the motor data

I

Tip!

The GDC "input assistant for motor data" makes motor parameterisation easy.
For more information, please see the "Global Drive Control (GDC) − Getting
started" Manual.
In "GDC Easy", the "Input assistant for motor data" is not available. In this
case, please contact your Lenze representative for the stator resistance and
leakage inductance data.

For the manual adjustment of the motor data, the following codes are provided to you:

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

[C0006] Op mode

1

Operating mode of the motor
control

l

If the master pulse (via
MCTRL: C0911 = 0 or DfIn:
C0428 = 0) is used, the
voltage supply has to be
switched off and then on
again when the operating
mode is changed.

l

Otherwise, the master pulses
will not be recognised.

1

Servo PM−SM

Servo control of synchronous
motors

2

Servo ASM

Servo control of asynchronous
motors

C0022 Imax current

à

I

max

limit

0

{0.01 A}

à

Device−dependent list

Max. current can be gathered
from the technical data.

C0077 Vp fieldCTRL

5.0

Field controller gain (V

pF

)

^ 144

0.00

{0.01}

63.99

C0078 Tn fieldCTRL

20.0

Field controller reset time (T

nF

)

^ 144

1.0

{0.5 ms}

6000.0

C0079 DIS:Lh

Mutual inductance of the
asynchronous motor
Read only

0.0

{0.1 mH}

3276.7

[C0080] Res pole no.

1

Number of pole pairs of resolver

1

{1}

10

[C0081] Mot power

3.20

Rated motor power according to
nameplate

0.01

{0.01 kW}

500.00

[C0082] DIS:Rr

Rotor resistance of the
asynchronous motor
Read only

0.000

{0.001

W}

32.767