Monitoring functions – Lenze ECSCAxxx User Manual

Page 207

Advertising
background image

Monitoring functions

Configuring monitoring functions

Motor temperature monitoring (OH3, OH7)

10

l

207

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0583 MONIT OH3

0

Fault response − monitoring of
motor temperature (fixed
temperature threshold).
Detection through KTY thermal
sensor via resolver input X7 or
encoder input X8.

^ 206

0

TRIP

2

Warning

3

Off

C0584 MONIT OH7

2

Fault response − motor
temperature monitoring
Temperature threshold can be
set under C0121.
Detection through KTY thermal
sensor via resolver input X7 or
encoder input X8.
Only effective if OH3 is switched
on under C0583.

^ 206

0

TRIP

2

Warning

3

Off

Advertising