Appendix

Code table

14

l

427

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C2461

Detected load
CANaux_IN/CANaux_OUT (CAN
bus interface X14)
Read only
A faultless operation is only
guaranteed if the total bus load
of all connected nodes amounts
to a value

£ 80 %.

^ 179

1 Load IN/OUT

0

{1 %}

100 All sent telegrams

2 Load IN/OUT

All received telegrams

3 Load IN/OUT

Sent to CANaux1_OUT

4 Load IN/OUT

Sent to CANaux2_OUT

5 Load IN/OUT

Sent to CANaux3_OUT

6 Load IN/OUT

Sent to parameter data
channel 1

7 Load IN/OUT

Sent to parameter data
channel 2

8 Load IN/OUT

Received from CANaux1_IN

9 Load IN/OUT

Received from CANaux2_IN

10 Load IN/OUT

Received from CANaux3_IN

11 Load IN/OUT

Received from parameter data
channel 1

12 Load IN/OUT

Received from parameter data
channel 2

C2466 Sync Response

1

CAN sync response for interface
X14 (CAN−AUX)
The value "1" should always be
set!

0

No response

1

Response

C2467 Sync Rx ID

128

CAN−AUX sync receipt ID for CAN
bus interface X14

^ 168

1

{1}

256

C2468 Sync Tx ID

128

CAN−AUX Sync−transmission ID
for CAN bus interface X14

^ 442

^ 169

1

{1}

256

C2469 Sync Tx time

0

CAN−AUX sync transmission cycle
for CAN bus interface X14
A sync telegram with the
identifier of C2468 is sent with
the set cycle time.

^ 166

^ 163

0

{1 ms}

65000 0 = switched off

C2470 ParWrite

0

CANaux channel used by
L_ParWrite/L_ParRead
(byComChannel = 11)

^ 180

0

Unused PDO channel free for
reconfiguration
(CANaux1...3_IN/CANaux1...3_OUT)

1

Parameter data channel 2