System modules

DFOUT_IO_DigitalFrequency (node number 22)
Inputs_DFOUT / Outputs_DFOUT

13

l

340

EDBCSXA064 EN 3.2

13.17.1.1

Configure encoder constant

Via C0030 you configure the encoder constant:

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0030 DFOUT const

3

Constant for the digital
frequency signal DFOUT_nOut_v
on X8 in increments per
revolution

^ 340

^ 115

^ 122

0

256 incr./rev

1

512 incr./rev

2

1024 incr./rev

3

2048 incr./rev

4

4096 incr./rev

5

8192 incr./rev

6

16384 incr./rev

Advertising