DFOUT_IO_DigitalFrequency (node number 22)
Inputs_DFOUT / Outputs_DFOUT
l
340
EDBCSXA064 EN 3.2
13.17.1.1
Configure encoder constant
Via C0030 you configure the encoder constant:
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0030 DFOUT const
3
Constant for the digital
frequency signal DFOUT_nOut_v
on X8 in increments per
revolution
^ 340
^ 115
^ 122
0
256 incr./rev
1
512 incr./rev
2
1024 incr./rev
3
2048 incr./rev
4
4096 incr./rev
5
8192 incr./rev
6
16384 incr./rev