20 mctrl_motorcontrol (node number 131), System modules, Mctrl_motorcontrol (node number 131) – Lenze ECSCAxxx User Manual

Page 351: Fig. 13−29 system block "mctrl_motorcontrol

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)

13

l

351

EDBCSXA064 EN 3.2

13.20

MCTRL_MotorControl (node number 131)

This SB contains the control of the driving machine. It consists of the phase controller,
speed controller, and the motor control.

C0907/3

C0042

C0105

100%

C0254

1

0

0

1

C0909

C0070

C0071

C0070

C0072

1

0

1

0

VECT_CTRL

PWM

C0050

C0056

C0006

C0091

C0090

C0089

C0088

C0087

C0085

C0084

C0081

C0078

C0077

C0076

C0075

C0022

C0018

UG-VOLTAGE

MONIT-LU

C0053

C0173

MONIT-OU

MONIT-OC1

const

Imotor

C0022

const

MONIT-OC2

>1,50I

NX

MONIT-OC5

const

X7

Resolver

X8

Encoder

C0420

C0495

C0490

C0419

C0051

C0011

C0497

C0607

MONIT-NMAX

const

MONIT-Sd2

OR

const

MONIT-Sd6

const

MONIT-Sd7/SD8

0
1
2
3
4

C0490

DI2

1

0

C0912

C0911

TP/MP

-Ctrl

C0910

C0906/4

C0906/3

C0907/2

C0907/4

C0906/8

C0906/5

C0907/1

C0906/6

C0906/2

C0906/7

C0906/1

C0906/9

C0908

+

-

MCTRL_MotorControl

0

1

C0579

C0576

MONIT nErr

150°C

MONIT-OH3

C0063

Mot temp (X7 or X8)

C0121

MONIT-OH7

85°C

MONIT-OH

C0061

Heatsink temp

C0122

MONIT-OH4

1

0

0

C0111

C0098

X6

MCTRL_nHiMLim_a

MCTRL_bQspOut_b

MCTRL_nLoMLim_a

MCTRL_bNMSwt_b

MCTRL_nNAdapt_a

MCTRL_bILoad_b

MCTRL_nISet_a

MCTRL_nNSet_a

MCTRL_nPAdapt_a

MCTRL_dnPosSet_p

MCTRL_bQspIn_b

MCTRL_nNSetIn_a

MCTRL_bMMax_b

MCTRL_nMSetIn_a

MCTRL_bIMax_b

MCTRL_nIAct_a

MCTRL_nDCVolt_a

MCTRL_nMAct_a

MCTRL_nPosLim_a

MCTRL_bPosOn_b

MCTRL_nNStartmLim_a

MCTRL_nMAdd_a

MCTRL_nFldWeak_a

MCTRL_bUnderVoltage_b

MCTRL_bOverVoltage_b

MCTRL_bShortCircuit_b

MCTRL_bEarthFault_b

MCTRL_bIxtOverload_b

MCTRL_nPos_a

MCTRL_nNAct_a

MCTRL_dnPos_p

MCTRL_bNmaxFault_b

MCTRL_nNmaxC11

MCTRL_nNAct_v

MCTRL_bResolverFault_b

MCTRL_bEncoderFault_b

MCTRL_bSensorFault_b

MCTRL_bActTPReceived_b

MCTRL_dnActIncLastScan_p

MCTRL_wMmaxC57

MCTRL_bMotorTempGreaterSetValue_b

MCTRL_bMotorTempGreaterC0121_b

MCTRL_bKuehlGreaterSetValue_b

MCTRL_bKuehlGreaterC0122_b

MCTRL_bRotorPositionFault_b

MONIT-PL

MCTRL_bMotorphaseFail_b

MONIT-LP1

ECSXA290

Fig. 13−29

System block "MCTRL_MotorControl"

)

Note!

The process image is established in the course of a fixed system task (interval:
1 ms).
Exception: MCTRL_bActTPReceived_b, MCTRL_dnActIncLastScan_p and
MCTRL_nNAct_v respectively are read in the process input image of the task in
which they are used.

Advertising