System modules

CANaux1_IO (node number 34)
Inputs_CANaux1

13

l

306

EDBCSXA064 EN 3.2

13.12.1

Inputs_CANaux1

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Comments

CANaux1_nInW0_a

integer

analog

%IW34.0

˘

˘

CANaux1_bInB0_b

%IX34.0.0

...

BOOL

binary

...

C2491/1

hex

CANaux1_bInB15_b

%IX34.0.15

CANaux1_nInW1_a

integer

analog

%IW34.1

C2492/1

dec [%]

CANaux1_bInB16_b

%IX34.1.0

...

BOOL

binary

...

C2491/2

hex

CANaux1_bInB31_b

%IX34.1.15

CANaux1_nInW2_a

integer

analog

%IW34.2

C2492/2

dec [%]

CANaux1_bInB32_b

%IX34.2.0

...

BOOL

binary

...

˘

˘

CANaux1_bInB47_b

%IX34.2.15

CANaux1_nInW3_a

integer

analog

%IW34.3

C2492/3

dec [%]

CANaux1_bInB48_b

%IX34.3.0

...

BOOL

binary

...

˘

˘

CANaux1_bInB63_b

%IX34.3.15

CANaux1_dnInD1_p

double

integer

position

%ID34.1

˘

˘

User data

The 8 bytes of received user data are assigned to several variables of different data types.
According to requirements, they can thus be evaluated by the PLC program as:

ƒ

binary information (1 bit)

ƒ

control word/quasi−analog value (16 bit)

ƒ

angle information (32 bit)

Byte

Variable (1 bit)

Variable (16 bit)

Variable (32 bit)

1, 2

CANaux1_bInB0_b

...

CANaux1_bInB15_b

CANaux1_nInW0_a

3, 4

CANaux1_bInB16_b

...

CANaux1_bInB31_b

CANaux1_nInW1_a

5, 6

CANaux1_bInB32_b

...

CANaux1_bInB47_b

CANaux1_nInW2_a

CANaux1_dnInD1_p

7, 8

CANaux1_bInB48_b

...

CANaux1_bInB63_b

CANaux1_nInW3_a