DIGITAL_IO (node number 1)

Inputs_DIGITAL (digital inputs)

13

l

343

EDBCSXA064 EN 3.2

13.18

DIGITAL_IO (node number 1)

13.18.1

Inputs_DIGITAL (digital inputs)

This SB reads and conditions the signals on X6/DI1 ... DI4.

ƒ

The configuration of the terminal polarity for the inputs X6/DI1 ... DI4 is effected via
C0114.

ƒ

The safety function "safe torque off" (former "safe standstill") is activated via X6/SI1
and X6/SI2.

C0443

X6

Inputs_DIGITAL

DI3

SI1

SI2

DI1

DI4

DI2

safe torque off

1

0

C0114/1...4

1

X6

C0443

mP

mP + Imp

DIGIN_bIn1_b

DIGIN_bIn2_b

DIGIN_b_safe_standstill_b

DIGIN_bIn4_b

DIGIN_bIn3_b

DIGIN_bCInh_b

ECSXA241

Fig. 13−26

System block "Inputs_DIGITAL"

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

DIGIN_bCInh_b

BOOL

binary

%IX1.0.0

˘

˘

Controller inhibit ˘ takes
direct effect on the
device control DCTRL.

DIGIN_bIn1_b

%IX1.0.1

C0443

bin

DIGIN_bIn2_b

%IX1.0.2

DIGIN_bIn3_b

%IX1.0.3

DIGIN_bIn4_b

%IX1.0.4

DIGIN_b_safe_standstill
_b

%IX1.0.5

"Safe torque off"
(former "safe standstill")