System bus (CAN / CAN−AUX) configuration

Setting the CAN node address and baud rate
Settings via codes

8

l

158

EDBCSXA064 EN 3.2

8.1.2

Settings via codes

)

Note!

ƒ

The settings in C0350/C2450 (CAN node address) and C0351/C2451 (baud
rate) are only used if the (address) switches 2 ... 7 of the DIP switch S1 are
switched off (OFF).

ƒ

If only one (address) switch 2 ... 7 is switched on (ON), the settings of the DIP
switch S1 usually apply.

ƒ

The baud rate (C0351/C2451) must be set identically for all CAN bus nodes.

ƒ

If the Lenze setting has been loaded via C0002,
– C0351/C2451 is set = 0 (500 kbits;
– you have to reset the baud rate (C0351/C2451) and the CAN node address

(C0350/C2450).

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0350 CAN address

32

Node address for CAN bus
interface X4

l

This code is not active if one
of the switches 2 ... 7 of the
DIP switch is set to "ON".
(

^ 156)

l

After the setting process, a
reset node is required.

l

A definite node address must
be assigned to each CAN
node.

^ 156

^ 458

1

{1}

63

C0351 CAN baud rate

0

Baud rate for CAN bus interface
X4

l

The baud rate must be set
identically for all CAN nodes.

l

This code is not active if one
of the switches 2 ... 7 of the
DIP switch is set to "ON".

l

After the setting process, a
reset node is required.

^ 156

0

500 kbps

1

250 kbits/sec

2

125 kbit/s

3

50 kbps

4

1000 kbit/s

C2450 CANa address

1

Node address for CAN bus
interface X14 (CAN−AUX)

^ 156

^ 458

1

{1}

63 This code is inactive if one of DIP

switches 2 ... 7 and switch 1 are
set to "ON".