System modules

AIF2_IO_AutomationInterface (node number 42)

Outputs_AIF2

13

l

269

EDBCSXA064 EN 3.2

13.3.2

Outputs_AIF2

This SB is used as an interface for output signals (e.g. setpoints/actual values) to attached
fieldbus modules (e.g. INTERBUS, PROFIBUS−DP).

The process image is

ƒ

created in the cyclic task by means of a fixed set time interval of 10 ms.

ƒ

created in an interval task within the time set for this task.

ƒ

read at the beginning of the task and written at its end.

,

Please read the documentation for the connected fieldbus module.

...

Byte

1

Byte

2

Byte

3

Byte

4

Byte

5

Byte

6

Byte

7

Byte

8

...

16 bits

Low Word

16 bits

High Word

16 bits

16 binary

signals

16 bits

16 binary

signals

16 bits

16 bits

X1

Outputs_AIF2

AIF2_nOutW2_a

AIF2_nOutW1_a

AIF2_bFDO0_b

AIF2_bFDO15_b

AIF2_bFDO16_b

AIF2_bFDO31_b

AIF2_nOutW4_a

AIF2_dnOutD1_p

AIF2_nOutW3_a

ECSXA204

Fig. 13−6

System block "Outputs_AIF2"

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

AIF2_nOutW1_a

Integer

analog

%QW42.0

˘

˘

AIF2_nOutW2_a

%QW42.1

AIF2_nOutW3_a

%QW42.2

AIF2_nOutW4_a

%QW42.3

AIF2_bFDO0_b

...

AIF2_bFDO15_b

Bool

binary

%QX42.0.0

...

%QX42.0.15

˘

˘

AIF2_bFDO16_b

...

AIF2_bFDO31_b

%QX42.1.0

...

%QX42.1.15

AIF2_dnOutD1_p

Double
Integer

position

%QD42.0

˘

˘