Appendix – Lenze ECSCAxxx User Manual

Page 415

Advertising
background image

Appendix

Code table

14

l

415

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0855

Digital process data input words
are indicated on the AIF interface
(AIF1_IN)
Hexadecimal value is bit−coded.
Read only

^ 259

1 AIF1 IN bits

0000

{hex}

FFFF Input word 2 (bit 0 ... 15)

2 AIF1 IN bits

Input word 3 (bit 0 ... 15)

C0856

Analog process data input words
are indicated decimally on the
AIF interface (AIF1_IN)
100.00% = 16384
Read only

^ 259

1 AIF1 IN words

−199.99

{0.01 %}

199.99 Input word 1

2 AIF1 IN words

Input word 2

3 AIF1 IN words

Input word 3

C0857 AIF1 IN phi

32 bits of phase information on
the AIF interface (AIF1_IN)
Read only

^ 259

−2147483648

{1}

2147483647

C0858

Analog process data output
words are indicated decimally on
the AIF interface (AIF1_OUT)
100.00% = 16384
Read only

^ 264

1 AIF1 OUT

words

−199.99

{0.01 %}

199.99 Output word 1

2 AIF1 OUT

words

Output word 2

3 AIF1 OUT

words

Output word 3

C0859 AIF1 OUT phi

32−bit phase information at the
AIF interface (AIF1_OUT)
Only display

^ 264

−2147483648

{1}

2147483647

C0863

Digital process data input words
for CAN bus interface X4
Hexadecimal value is bit−coded.
Read only

^ 446

0000

{hex}

FFFF

1 CAN IN bits

Bit 0

...

Bit15 CAN1_IN: Process data input

word 1

2 CAN IN bits

Bit 16

...

Bit 31 CAN1_IN: Process data input

word 2

3 CAN IN bits

Bit 0

...

Bit15 CAN2_IN: Process data input

word 1

4 CAN IN bits

Bit 16

...

Bit 31 CAN2_IN: Process data input

word 2

5 CAN IN bits

Bit 0

...

Bit15 CAN3_IN: Process data input

word 1

6 CAN IN bits

Bit 16

...

Bit 31 CAN3_IN: Process data input

word 2

Advertising