background image

System modules

AIF3_IO_AutomationInterface (node number 43)
Inputs_AIF3

13

l

272

EDBCSXA064 EN 3.2

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

AIF3_nInW1_a

Integer

analog

%IW43.0

˘

˘

AIF3_nInW2_a

%IW43.1

AIF3_nInW3_a

%IW43.2

AIF3_nInW4_a

%IW43.3

AIF3_bInB0_b

...

AIF3_bInB15_b

Bool

binary

%IX43.0.0

...

%IX43.0.15

˘

˘

AIF3_bInB16_b

...

AIF3_bInB31_b

%IX43.1.0

...

%IX43.1.15

AIF3_dnInD1_p

Double
Integer

position

%ID43.0

˘

˘

User data

The first 4 bytes from the 8 bytes of received user data are assigned to several variables of
different data types. According to requirements, they thus can be evaluated by the PLC
program as:

ƒ

binary information (1 bit)

ƒ

quasi−analog value (16 bit)

ƒ

angle information (32 bit)

Byte

Variable (1 bit)

Variable (16 bit)

Variable (32 bit)

1, 2

AIF3_bInB0_b

...

AIF3_bInB15_b

AIF3_nInW1_a

AIF3_dnInD1_p

3, 4

AIF3_bInB16_b

...

AIF3_bInB31_b

AIF3_nInW2_a

5, 6

AIF3_nInW3_a

7, 8

AIF3_nInW4_a