2 overview of monitoring functions, Monitoring functions, Overview of monitoring functions – Lenze ECSCAxxx User Manual

Page 198

Advertising
background image

Monitoring

functions

Overview of monitoring functions

10

l

198

EDBCSXA064

EN 3.2

10.2

Overview of monitoring functions

Monitoring

Possible fault responses

l Lenze setting

ü Can be set

Fault message

Description

Source

Code

TRIP

Message

Warning

Fail−QSP

Off

x071

CCR

System fault

Internal

l

x091

EEr

External monitoring (activated via DCTRL)

FWM

C0581

l

ь

ь

ь

ь

x191

HSF

Internal error

Internal

l

Voltage supply

1020

OU

Overvoltage in the DC bus (C0173)

MCTRL

l

1030

LU

Undervoltage in the DC bus(C0174)

MCTRL

l

0070

U15

Undervoltage of internal 15 V voltage supply

Internal

l

0107

H07

Internal fault (power section)

Internal

l

Communication

x041

AP1

Internal fault (signal processor)

Internal

l

x061

CE0

Communication error on the automation interface (AIF)

AIF

C0126

ь

ь

l

x062

CE1

Communication error on the CAN1_IN process data input object
(monitoring time adjustable via C0357/1)

CAN1_IN

C0591

ь

ь

l

x063

CE2

Communication error on the CAN2_IN process data input object
(monitoring time adjustable via C0357/2)

CAN2_IN

C0592

ь

ь

l

x064

CE3

Communication error on the CAN3_IN process data input object
(monitoring time adjustable via C0357/3)

CAN3_IN

C0593

ь

ь

l

x065

CE4

BUS−OFF state CAN bus at interface X4 (CAN)
(too many faulty telegrams)

CAN

C0595

ь

ь

l

x066

CE5

Communication error of the gateway function (C0370, C0371) via CAN bus
at interface X4 (CAN)

CAN

C0603

ь

ь

l

x122

CE11

Communication error on the CANaux1_IN process data input object ( time
monitoring adjustable via C2457/1)

CANaux1_IN

C2481

ь

ь

l

x123

CE12

Communication error on the CANaux2_IN process data input object ( time
monitoring adjustable via C2457/2)

CANaux2_IN

C2482

ь

ь

l

x124

CE13

Communication error on the CANaux3_IN process data input object ( time
monitoring adjustable via C2457/3)

CANaux3_IN

C2483

ь

ь

l

x125

CE14

BUS−OFF state CAN bus at interface X14 (CAN−AUX)
(too many faulty telegrams)

CANaux

C2484

ь

ь

l

x: 0 = TRIP, 1 = message, 2 = warning, 3 = FAIL−QSP

1)

Adjustable in the DDS under Project

W Exceptional handling

2)

For ECSxA... only