System bus (can / can−aux) configuration – Lenze ECSCAxxx User Manual

Page 161

Advertising
background image

System bus (CAN / CAN−AUX) configuration

Individual addressing

8

l

161

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0354

Alternative node address for
CAN_IN/CAN_OUT (CAN bus
interface X4)

^ 160

1 CAN addr.

129

1

{1}

512 Address 2 CAN1_IN

2 CAN addr.

1

Address 2 CAN1_OUT

3 CAN addr.

257

Address 2 CAN2_IN

4 CAN addr.

258

Address 2 CAN2_OUT

5 CAN addr.

385

Address 2 CAN3_IN

6 CAN addr.

386

Address 2 CAN3_OUT

C2453

Source for system bus node
addresses of
CANaux_IN/CANaux_OUT (CAN
bus interface X14)

^ 160

1 CANa addr sel

0

CAN node address (C2450)

Address CANaux1_IN/OUT

2 CANa addr sel

0

CAN node address (C2450)

Address CANaux2_IN/OUT

3 CANa addr sel

0

CAN node address (C2450)

Address CANaux3_IN/OUT

0

C2450 (auto)

Automatically determined by
C2450

1

C2454 (man.)

Determined by C2454

C2454

Alternative node addresses for
CANaux_IN/CANaux_OUT (CAN
bus interface X14)

^ 160

1 CANa addr.

129

1

{1}

512 CANaux1_INaddress 2

2 CANa addr.

1

CANaux1_OUTaddress 2

3 CANa addr.

257

CANaux2_INaddress 2

4 CANa addr.

258

CANaux2_OUTaddress 2

5 CANa addr.

385

CANaux3_IN address 2

6 CANa addr.

386

CANaux3_OUT address 2

Save changes with C0003 = 1.

The settings are only accepted after carrying out one of the following actions:

ƒ

Renewed switch−on of the 24 V low−voltage supply

ƒ

Reset node via the bus system (by the network management (NMT))

ƒ

Variable CAN_bResetNode_b or CANaux_bResetNode_b = TRUE

ƒ

Reset node with C0358/2458 = 1

)

Note!

If reset node is executed via GDC, communication will be interrupted. You
therefore have to log in again manually or find the devices connected to the
bus once again (fieldbus scan).