4 access via absolute addresses, 5 definition of the inputs/outputs, Access via absolute addresses – Lenze ECSCAxxx User Manual

Page 24: Definition of the inputs/outputs, Preface and general information

Advertising
background image

Preface and general information

System block introduction
Access via absolute addresses

1

l

24

EDBCSXA064 EN 3.2

1.5.4

Access via absolute addresses

You can also access the inputs and outputs of the system blocks via absolute addresses
according to standard IEC 61131−3:

For inputs:

For outputs:

%IXa.b.c

%QXa.b.c

a = node number
b = word address
c = bit address

In this Manual, the absolute addresses can be retrieved in the system variable table of the
corresponding system block.

Example: Table with the inputs of the SB Inputs_Digital of the ECSxA... axis module

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

DIGIN_bCInh_b

BOOL

binary

%IX1.0.0

˘

˘

Controller inhibit ˘ takes
direct effect on the
device control DCTRL.

DIGIN_bIn1_b

%IX1.0.1

C0443

bin

DIGIN_bIn2_b

%IX1.0.2

DIGIN_bIn3_b

%IX1.0.3

DIGIN_bIn4_b

%IX1.0.4

DIGIN_b_safe_standstill_b

%IX1.0.5

"Safe torque off"
(former "safe standstill")

1.5.5

Definition of the inputs/outputs

For connecting the application program with the hardware, system blocks are connected
with program organisation units (POU):

SB

SB-Output

POE-Input

POE-Output

SB-Input

SB

POE

Fig. 1−1

Plan: Connecting system blocks to a program organisation unit (POU)

)

Note!

Inputs and outputs are always classified from the program’s point of view.

ƒ

Logical SB inputs are always hardware−side outputs of the ECSxA axis...
module

ƒ

Logical SB outputs are always hardware−side inputs of the ECSxA axis...
module