System modules – Lenze ECSCAxxx User Manual

Page 344

Advertising
background image

System modules

DIGITAL_IO (node number 1)
Inputs_DIGITAL (digital inputs)

13

l

344

EDBCSXA064 EN 3.2

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0114

Polarity of the digital inputs

^ 129

1 DIGIN pol

0

HIGH level active

X6/DI1 (DIGIN_bIn1_b)

2 DIGIN pol

0

HIGH level active

X6/DI2 (DIGIN_bIn2_b)

3 DIGIN pol

0

HIGH level active

X6/DI3 (DIGIN_bIn3_b)

4 DIGIN pol

0

HIGH level active

X6/DI4 (DIGIN_bIn4_b)

0

HIGH level active

1

LOW level active

C0443 DIS: DIGIN

Signal status of the digital inputs
on X6 after consideration of the
polarity set under C0114.
Only display

^ 343

0

{1}

255

Bit 0

DIGIN1

X6/DI1

Bit 1

DIGIN2

X6/DI2

Bit 2

DIGIN3

X6/DI3

Bit 3

DIGIN4

X6/DI4

Bit 4

DIGIN_safe_standstill

X6/SI2
0: Pulse inhibit is active
1: Pulse inhibit is inactive

^ 80

Bit 5

Free

Bit 6

DIGIN_CInh

X6/SI1
0: Controller is inhibited (CINH)
1: Controller is enabled

^ 80

Bit 7

Free

Terminal assignment

Terminal

Function

X6

Digital inputs

X6/DI1

Digital input 1
(DigIn_bIn1_b)

freely assignable

X6/DI2

Digital input 2
(DigIn_bIn2_b)

X6/DI3

Digital input 3
(DigIn_bIn3_b)

X6/DI4

Digital input 4
(DigIn_bIn4_b)

X6

Connection of "Safe torque off"(

^ 80)

X6/SI1

Input 1

LOW

DIGIN_bCInh_b = TRUE

HIGH

DIGIN_bCInh_b = FALSE

X6/SI2

Input 2

LOW

DIGIN_b_safe_standstill_b = FALSE

HIGH

DIGIN_b_safe_standstill_b = TRUE

X6/S24

Low−voltage supply

Advertising
This manual is related to the following products: