System modules

AIF1_IO_AutomationInterface (node number 41)
Outputs_AIF1

13

l

264

EDBCSXA064 EN 3.2

13.2.2

Outputs_AIF1

This SB is used as an interface for output signals (e.g. setpoints/actual values) to attached
fieldbus modules (e.g. INTERBUS, PROFIBUS−DP).

The process image is

ƒ

created in the cyclic task by means of a fixed set time interval of 10 ms.

ƒ

created in an interval task within the time set for this task.

ƒ

read at the beginning of the task and written at its end.

,

Please read the documentation for the connected fieldbus module.

Byte

1

Byte

2

Byte

3

Byte

4

Byte

5

Byte

6

Byte

7

Byte

8

C0858/1

16 Bit

LowWord

16 Bit

HighWord

16 Bit

16 Bit

C0858/2

C0858/3

C0859

16 Bit

16 binary

signals

16 Bit

16 binary

signals

Outputs_AIF1

X1

AIF1_wDctrlStat

AIF1_nOutW1_a

AIF1_nOutW2__a

AIF1_bFDO0_b

AIF1_bFDO15_b

AIF1_nOutW3_a

AIF1_bFDO16_b

AIF1_bFDO31_b

AIF1_dnOutD1_p

ECSXA202

Fig. 13−4